top of page

The CO2 sensors with current output 4 to 20 mA - SC 500 is designed to measure the carbon dioxide concentration of the air in spaces protected against water.
The CO2 sensors with current output 4 to 20 mA - SC 500 consists of a plastic ribbing head where a printed circuit board with the CO2 sensor and a converter is placed to establish a communication via current output 4 to 20 mA. The CO2 value is measured by a NDIR module whose output signal is also converted to an output signal 4 to 20 mA. For the CO2 concentration sensor SC 500, there is an autocalibration function available to set the sensor at the minimum CO2 value corresponding to the outside concentration level. The CO2 sensors with current output 4 to 20 mA - SC 500 meets the ingress protection of IP 30 according to EN 60529, as amended. Suitable design and high-quality material ensure that the sensor does not feel disturbing even in the interiors with high aesthetic requirements. You can choose the color of the box white or gray.
The CO2 sensors with current output 4 to 20 mA - SC 500 is designed to be operated in a chemically non-aggressive environment; its use must be chosen with regard to temperature and chemical resistance of the head and of the individual sensors. The operating conditions to establish the correct function are:

  • ambient temperature in the vicinity of the sensor: 0 to 45 °C
  • relative ambient humidity: 0 to 95% (non-condensing humidity)
  • atmospheric pressure: 87 to 106 kPa

TESTS, DECLARATION, CALIBRATIONS

  • Manufacturer provides EU Declaration of Conformity.
  • Calibration – The final metrological inspection – comparison with standards or working instruments – is carried out for all the products. Continuity of the standards and working measuring instruments is ensured within the meaning of the Section 5 of Act no.505/1990 on metrology. The manufacturer offers a possibility to supply the sensors calibrated in SENSIT s.r.o.’s laboratory (according to requirements of the EN ISO/IEC 17025 standard, as amended) or in an Accredited laboratory.

 

 

  • SPECIFICATIONS
  • DIMENSIONAL DRAFT
  • WIRING DIAGRAM
  • DOWNLOAD
Sensor typeSC 500
Measured valuesCO2
Output signal4 to 20 mA
CO2 measuring range *400 to 5000 ppm
CO2 measuring accuracy *± 50 ppm *
Time response CO2 (90%)20 s
Supply voltage U15 to 30 VDC
Rated supply voltage Un24 VDC
Consumptionmaximal: 500 mW
typical: 300 mW
Ingress protectionIP 30 in accordance with EN 60529, as amended
Dimension of the head71.9 x 59 x 27 mm
Material of the headLEXAN
Weightmin 35 g
Recommended wire cross section0.14 to 1 mm2

* The stated measurement ranges and accuracies for the individual sensors refer to operating conditions when the supply voltage is connected.

Note: Manufacturer reserves the right to make changes in design and technical characteristics of the products. For actual information, please always contact your dealer.

SC 500 – CO2 SENSOR WITH CURRENT OUTPUT 4 TO 20 mA

0.00 ₪מחיר